{"product_id":"st6-m1","title":"ST6-M1","description":"\u003cp data-start=\"148\" data-end=\"747\"\u003eThe ST-6M1 is a high-performance sequential timing controller from Electronic Automation Pvt Ltd (EAPL) designed for multi-step automation sequences. With six independent channels, each channel can be assigned an ON-time and OFF-time in sequence, enabling controlled startup\/shutdown of multiple loads in a fixed order. This makes the ST-6M1 ideal for applications such as motor control, fans\/blowers, pump sequencing, dust-collection systems, air-handling units and other systems where loads must come online or go offline in a staged manner. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"749\" data-end=\"768\"\u003e\u003cstrong data-start=\"749\" data-end=\"766\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"769\" data-end=\"2051\"\u003e\n\u003cli data-start=\"769\" data-end=\"941\"\u003e\n\u003cp data-start=\"771\" data-end=\"941\"\u003eSix independent output channels: The timer progresses from CH1 through CH6, applying each channel’s ON and OFF times sequentially.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"942\" data-end=\"1143\"\u003e\n\u003cp data-start=\"944\" data-end=\"1143\"\u003eWide time-range: From \u003cstrong data-start=\"966\" data-end=\"1008\"\u003e0.1 seconds up to 99 hours, 59 minutes\u003c\/strong\u003e for each ON\/OFF period — giving flexibility from very short pulses to long duration intervals. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1300\"\u003e\n\u003cp data-start=\"1146\" data-end=\"1300\"\u003eSupply voltage variant: 85-270 V AC\/DC (depending on version) — supports broad industrial control system voltages. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1301\" data-end=\"1472\"\u003e\n\u003cp data-start=\"1303\" data-end=\"1472\"\u003eSelectable operation mode: Single-cycle (stop after channel 6) or cyclic (auto-wrap-around to channel 1) via external link C1-C2.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1473\" data-end=\"1710\"\u003e\n\u003cp data-start=\"1475\" data-end=\"1510\"\u003ePower-failure behaviour selection:\u003c\/p\u003e\n\u003cul data-start=\"1513\" data-end=\"1710\"\u003e\n\u003cli data-start=\"1513\" data-end=\"1568\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1568\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1528\"\u003eHOLD mode\u003c\/strong\u003e—timing resumes from where it left off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1710\"\u003e\n\u003cp data-start=\"1573\" data-end=\"1710\"\u003e\u003cstrong data-start=\"1573\" data-end=\"1589\"\u003eRESTART mode\u003c\/strong\u003e—sequence returns to channel 1 or waits for start signal after power restoration. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1711\" data-end=\"1902\"\u003e\n\u003cp data-start=\"1713\" data-end=\"1902\"\u003eExternal controls: Start signal (S1-S2) triggers the sequence; time-pause input (I1-I2) allows temporary halt of timing with relay status maintained. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1903\" data-end=\"2051\"\u003e\n\u003cp data-start=\"1905\" data-end=\"2051\"\u003eFeedback output: Cycle complete output (O1-O2) available at end of one full sequence in single-cycle mode. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2053\" data-end=\"2072\"\u003e\u003cstrong data-start=\"2053\" data-end=\"2070\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2073\" data-end=\"2530\"\u003e\n\u003cli data-start=\"2073\" data-end=\"2184\"\u003e\n\u003cp data-start=\"2075\" data-end=\"2184\"\u003eSequential startup of multiple motors or heavy loads to prevent large inrush current by staging each start.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2185\" data-end=\"2297\"\u003e\n\u003cp data-start=\"2187\" data-end=\"2297\"\u003eAutomating processes where one load must complete its operation (ON-time + OFF-time) before the next begins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2298\" data-end=\"2422\"\u003e\n\u003cp data-start=\"2300\" data-end=\"2422\"\u003eControl panels in dust-collection or ventilation systems where fan banks or blower groups must be activated in sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2423\" data-end=\"2530\"\u003e\n\u003cp data-start=\"2425\" data-end=\"2530\"\u003eRetrofitting automation into older switch-gear or control cabinets with clear channel sequencing logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50749907009824,"sku":null,"price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/ChatGPTImageSep30_2025_05_04_02PM.png?v=1759262670","url":"https:\/\/starpowerelectrical.com\/products\/st6-m1","provider":"My Store","version":"1.0","type":"link"}