{"product_id":"b1dca-t","title":"B1DCA-T","description":"\u003ch2 data-start=\"134\" data-end=\"170\"\u003e\u003cstrong data-start=\"137\" data-end=\"170\"\u003eB1DCA-T – Product Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"172\" data-end=\"513\"\u003e\n\u003cli data-start=\"172\" data-end=\"249\"\u003e\n\u003cp data-start=\"174\" data-end=\"249\"\u003eThe B1DCA-T is a \u003cstrong data-start=\"191\" data-end=\"225\"\u003ecyclic adjustable ON\/OFF timer\u003c\/strong\u003e from EAPL’s B-Series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"250\" data-end=\"342\"\u003e\n\u003cp data-start=\"252\" data-end=\"342\"\u003eProvides \u003cstrong data-start=\"261\" data-end=\"287\"\u003eindependent adjustment\u003c\/strong\u003e of ON and OFF times with multiple selectable ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"343\" data-end=\"411\"\u003e\n\u003cp data-start=\"345\" data-end=\"411\"\u003eEquipped with \u003cstrong data-start=\"359\" data-end=\"385\"\u003eHold\/Restart functions\u003c\/strong\u003e for flexible operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"412\" data-end=\"513\"\u003e\n\u003cp data-start=\"414\" data-end=\"513\"\u003eCompact DIN-rail or panel-mountable design with user-friendly rotary knobs and selector switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"515\" data-end=\"518\"\u003e\n\u003ch2 data-start=\"520\" data-end=\"545\"\u003e\u003cstrong data-start=\"523\" data-end=\"545\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"547\" data-end=\"1805\"\u003e\n\u003cli data-start=\"547\" data-end=\"618\"\u003e\n\u003cp data-start=\"549\" data-end=\"618\"\u003eFunction: Cyclic ON\/OFF timer with adjustable ON and OFF intervals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"619\" data-end=\"742\"\u003e\n\u003cp data-start=\"621\" data-end=\"742\"\u003eSupply Voltage: Wide operating range (AC and DC, typically 24 V to 240 V AC and 24 V to 220 V DC for X-version models).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"743\" data-end=\"821\"\u003e\n\u003cp data-start=\"745\" data-end=\"821\"\u003eTime Range: 0.6 seconds to 60 minutes with selectable ranges via switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"822\" data-end=\"915\"\u003e\n\u003cp data-start=\"824\" data-end=\"915\"\u003eOutput: 2 change-over (C\/O) relay contacts, rated 5 A at 250 VAC \/ 28 VDC resistive load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"916\" data-end=\"975\"\u003e\n\u003cp data-start=\"918\" data-end=\"975\"\u003ePower Consumption: Approximately 5 VA (AC) or 1 W (DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"976\" data-end=\"1073\"\u003e\n\u003cp data-start=\"978\" data-end=\"1073\"\u003eRange Selection: Multiple ranges (e.g., seconds to minutes) selectable using the front panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1212\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1087\"\u003eAccuracy:\u003c\/p\u003e\n\u003cul data-start=\"1090\" data-end=\"1212\"\u003e\n\u003cli data-start=\"1090\" data-end=\"1139\"\u003e\n\u003cp data-start=\"1092\" data-end=\"1139\"\u003eSetting accuracy: ±10% of full scale ±100 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1142\" data-end=\"1175\"\u003e\n\u003cp data-start=\"1144\" data-end=\"1175\"\u003eRepeat accuracy: ±1% ±100 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1178\" data-end=\"1212\"\u003e\n\u003cp data-start=\"1180\" data-end=\"1212\"\u003eRecovery time: Minimum 100 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1373\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1239\"\u003eEnvironmental Ratings:\u003c\/p\u003e\n\u003cul data-start=\"1242\" data-end=\"1373\"\u003e\n\u003cli data-start=\"1242\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1286\"\u003eOperating temperature: –10 °C to +55 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1331\"\u003e\n\u003cp data-start=\"1291\" data-end=\"1331\"\u003eStorage temperature: –25 °C to +80 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1334\" data-end=\"1373\"\u003e\n\u003cp data-start=\"1336\" data-end=\"1373\"\u003eHumidity: Up to 85–95% RH at 40 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1374\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1376\" data-end=\"1391\"\u003eService Life:\u003c\/p\u003e\n\u003cul data-start=\"1394\" data-end=\"1495\"\u003e\n\u003cli data-start=\"1394\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1396\" data-end=\"1442\"\u003eMechanical: ≥1 million operations (no load).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1445\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1447\" data-end=\"1495\"\u003eElectrical: ≥100,000 operations at rated load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1532\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1532\"\u003eInsulation: \u0026gt;100 MΩ at 500 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1533\" data-end=\"1687\"\u003e\n\u003cp data-start=\"1535\" data-end=\"1687\"\u003eDielectric Strength: Withstands up to 2.5 kV AC between key parts, 1.5 kV AC between contacts\/control, 1.0 kV AC across non-continuous relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1688\" data-end=\"1739\"\u003e\n\u003cp data-start=\"1690\" data-end=\"1739\"\u003eTerminals: Screw-type with self-lifting clamps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1805\"\u003e\n\u003cp data-start=\"1742\" data-end=\"1805\"\u003eDimensions: Approximately 45 mm (W) × 75 mm (H) × 116 mm (D).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1807\" data-end=\"1810\"\u003e\n\u003ch2 data-start=\"1812\" data-end=\"1831\"\u003e\u003cstrong data-start=\"1815\" data-end=\"1831\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1833\" data-end=\"2243\"\u003e\n\u003cli data-start=\"1833\" data-end=\"1897\"\u003e\n\u003cp data-start=\"1835\" data-end=\"1897\"\u003eLubrication systems requiring timed cyclic ON\/OFF operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1898\" data-end=\"1960\"\u003e\n\u003cp data-start=\"1900\" data-end=\"1960\"\u003eDiesel generator (DG) sets for periodic control functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1961\" data-end=\"2011\"\u003e\n\u003cp data-start=\"1963\" data-end=\"2011\"\u003ePumps and compressors in industrial processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2012\" data-end=\"2058\"\u003e\n\u003cp data-start=\"2014\" data-end=\"2058\"\u003ePackaging, textile, and process machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2059\" data-end=\"2117\"\u003e\n\u003cp data-start=\"2061\" data-end=\"2117\"\u003eLighting and heating systems requiring cyclic control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2118\" data-end=\"2179\"\u003e\n\u003cp data-start=\"2120\" data-end=\"2179\"\u003eAlarm and signaling systems with repetitive timing needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2180\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2182\" data-end=\"2243\"\u003eAutomation and MCC panels for sequential cyclic operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2245\" data-end=\"2248\"\u003e\n\u003ch2 data-start=\"2250\" data-end=\"2264\"\u003e\u003cstrong data-start=\"2253\" data-end=\"2264\"\u003eSummary\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2266\" data-end=\"2640\"\u003e\n\u003cli data-start=\"2266\" data-end=\"2347\"\u003e\n\u003cp data-start=\"2268\" data-end=\"2347\"\u003eThe \u003cstrong data-start=\"2272\" data-end=\"2283\"\u003eB1DCA-T\u003c\/strong\u003e is a versatile cyclic timer with adjustable ON and OFF times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2348\" data-end=\"2446\"\u003e\n\u003cp data-start=\"2350\" data-end=\"2446\"\u003eProvides high accuracy, repeatability, and flexible control features such as Hold and Restart.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2447\" data-end=\"2518\"\u003e\n\u003cp data-start=\"2449\" data-end=\"2518\"\u003eCompact, durable, and designed for industrial control environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2519\" data-end=\"2640\"\u003e\n\u003cp data-start=\"2521\" data-end=\"2640\"\u003eIdeal for applications in automation panels, DG sets, pumps, and process industries requiring precise cyclic control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50648553357600,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/ChatGPTImageAug30_2025_04_06_53AM.png?v=1756512427","url":"https:\/\/starpowerelectrical.com\/products\/b1dca-t","provider":"My Store","version":"1.0","type":"link"}