{"product_id":"apd-600","title":"APD - 600","description":"\u003cp data-start=\"173\" data-end=\"498\"\u003eThe APD-600 is a high-performance anti-pumping relay designed for medium and low-voltage switchgear and control panels. It prevents repeated or unintended re-closing of circuit breakers or contactors when the closing circuit remains engaged, thereby protecting your equipment and enhancing system reliability.\u003c\/p\u003e\n\u003cp data-start=\"500\" data-end=\"519\"\u003e\u003cstrong data-start=\"500\" data-end=\"517\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"520\" data-end=\"1282\"\u003e\n\u003cli data-start=\"520\" data-end=\"667\"\u003e\n\u003cp data-start=\"522\" data-end=\"667\"\u003ePrevents “pumping” — that is, a close command being held while a fault or trip condition still exists, resulting in repeated close-open cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"668\" data-end=\"874\"\u003e\n\u003cp data-start=\"670\" data-end=\"874\"\u003eRapid response: The product listing indicates a response time of approximately 20 ms for the APD-600 (“Rly 4C\/O. ‘X’ Vtg. 20 mS”) which implies very fast operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"994\"\u003e\n\u003cp data-start=\"877\" data-end=\"994\"\u003eFour change-over (C\/O) relay contacts for flexible wiring or interlock logic. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"995\" data-end=\"1130\"\u003e\n\u003cp data-start=\"997\" data-end=\"1130\"\u003e“X-Vtg” (wide-voltage) variant offering flexibility across control-voltages and applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.switchgearandautomation.com\/eapl-pricelist\/EAPL_%20PRICE%20LIST_01.04.25.pdf?utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.switchgearandautomation.com\/eapl-pricelist\/EAPL_%20PRICE%20LIST_01.04.25.pdf?utm_source=chatgpt.com\" class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]!\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between\"\u003e\u003cspan class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1131\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1133\" data-end=\"1282\"\u003eCompact, panel-friendly format, facilitating installation in MCCs, automation panels and distribution boards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1284\" data-end=\"1303\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1301\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1304\" data-end=\"1758\"\u003e\n\u003cli data-start=\"1304\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1306\" data-end=\"1495\"\u003eUse in motor control centres (MCCs) and control panels where circuit-breaker\/contactor closing coils are used and there’s a risk of holding the close push-button beyond the safe interval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1649\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1649\"\u003eIdeal for switchgear assemblies in industrial plants, utilities, commercial buildings and any system requiring protected, reliable breaker operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1650\" data-end=\"1758\"\u003e\n\u003cp data-start=\"1652\" data-end=\"1758\"\u003eSuitable for systems requiring both safety interlocking and indication logic due to its multiple contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50749809983776,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/ChatGPTImageSep30_2025_04_11_23PM.png?v=1759260016","url":"https:\/\/starpowerelectrical.com\/products\/apd-600","provider":"My Store","version":"1.0","type":"link"}