{"product_id":"a1d1-8-30v-dc","title":"A1D1 (8-30V DC)","description":"\u003cp data-start=\"105\" data-end=\"157\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe \u003cstrong data-start=\"4\" data-end=\"17\"\u003eEAPL A1D1\u003c\/strong\u003e is a compact, high-precision \u003cstrong data-start=\"47\" data-end=\"65\"\u003eOn‑Delay Timer\u003c\/strong\u003e, engineered for DC-powered industrial control systems. Utilizing an \u003cstrong data-start=\"134\" data-end=\"147\"\u003e8–30 V DC\u003c\/strong\u003e input, it delivers reliable timing and automation in a DIN-sized form factor ideal for panel and rail mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"159\" data-end=\"183\"\u003e\u003cstrong data-start=\"159\" data-end=\"181\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"186\" data-end=\"263\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"18\" data-is-only-node=\"\"\u003eSupply Voltage\u003c\/strong\u003e: 8 V DC to 30 V DC\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"266\" data-end=\"343\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"12\" data-is-only-node=\"\"\u003eFunction\u003c\/strong\u003e: On‑Delay timer — output relay activates only after the preset delay\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"346\" data-end=\"423\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"14\" data-is-only-node=\"\"\u003eTime Range\u003c\/strong\u003e: Adjustable from \u003cstrong data-start=\"32\" data-end=\"61\" data-is-last-node=\"\"\u003e0.3 seconds to 30 minutes\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"426\" data-end=\"503\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"10\" data-is-only-node=\"\"\u003eOutput\u003c\/strong\u003e: Dual form‑C, \u003cstrong data-start=\"25\" data-end=\"41\"\u003e2 C\/O relays\u003c\/strong\u003e for flexible control logic\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"506\" data-end=\"587\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"18\" data-is-only-node=\"\"\u003eContact Rating\u003c\/strong\u003e: Up to \u003cstrong data-start=\"26\" data-end=\"33\"\u003e5 A\u003c\/strong\u003e at \u003cstrong data-start=\"37\" data-end=\"49\"\u003e250 V AC\u003c\/strong\u003e or \u003cstrong data-start=\"53\" data-end=\"64\"\u003e30 V DC\u003c\/strong\u003e (resistive load)\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"590\" data-end=\"671\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"12\" data-is-only-node=\"\"\u003eMounting\u003c\/strong\u003e: DIN‑rail or screw‑mountable enclosure (~22.5 mm W × 75 mm H × 102 mm D)\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"674\" data-end=\"755\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"18\" data-is-only-node=\"\"\u003eLED Indicators\u003c\/strong\u003e: Integrated LEDs show both power and relay\/timing status\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"758\" data-end=\"839\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"21\" data-is-only-node=\"\"\u003eBuilt-in Features\u003c\/strong\u003e: Includes HOLD\/RESTART function for power‑fail resilience, programmable “Program Enable\/Disable” for tamper prevention, and Auto\/Manual operation mode\u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"841\" data-end=\"901\"\u003e\u003cstrong data-start=\"841\" data-end=\"857\"\u003eApplications\u003c\/strong\u003e\u003cbr data-start=\"857\" data-end=\"860\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eOptimized for use in industrial environments including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"904\" data-end=\"945\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eAMF (Auto Mains Failure) control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"948\" data-end=\"989\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eHT\/LT switchgear panels\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"992\" data-end=\"1033\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eMotor Control Centers (MCC)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1036\" data-end=\"1077\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eTransformer and RTCC panels\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1080\" data-end=\"1161\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eAutomation, control, and process panels requiring reliable delay functions\u003c\/span\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1163\" data-end=\"1186\"\u003e\u003cstrong data-start=\"1163\" data-end=\"1186\"\u003eAdvantages Snapshot\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1187\" data-end=\"1655\"\u003e\n\u003cli data-start=\"1187\" data-end=\"1270\"\u003e\n\u003cp data-start=\"1189\" data-end=\"1270\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1220\"\u003eWide DC input compatibility\u003c\/strong\u003e ensures versatility across low-voltage systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1271\" data-end=\"1377\"\u003e\n\u003cp data-start=\"1273\" data-end=\"1377\"\u003e\u003cstrong data-start=\"1273\" data-end=\"1295\"\u003eDual relay outputs\u003c\/strong\u003e allow for versatile control scenarios (e.g., cascading or redundant switching).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1459\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1459\"\u003e\u003cstrong data-start=\"1380\" data-end=\"1410\"\u003eBroad timing adjustability\u003c\/strong\u003e suits both quick operations and longer delays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1566\"\u003e\n\u003cp data-start=\"1462\" data-end=\"1566\"\u003e\u003cstrong data-start=\"1462\" data-end=\"1494\"\u003eIndustrial-grade reliability\u003c\/strong\u003e through LED indicators, safety covers, and durability-focused design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1567\" data-end=\"1655\"\u003e\n\u003cp data-start=\"1569\" data-end=\"1655\"\u003e\u003cstrong data-start=\"1569\" data-end=\"1588\"\u003eSpace-efficient\u003c\/strong\u003e profile fits neatly into panel systems, streamlining installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50591473434912,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/Professional_product_photography-2.jpg?v=1754022336","url":"https:\/\/starpowerelectrical.com\/products\/a1d1-8-30v-dc","provider":"My Store","version":"1.0","type":"link"}