{"title":"Anti Pumping Relays","description":"","products":[{"product_id":"apd-100","title":"APD-100","description":"\u003ch2 data-start=\"126\" data-end=\"162\"\u003e\u003cstrong data-start=\"129\" data-end=\"162\"\u003eAPD-100 – Product Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"164\" data-end=\"585\"\u003e\n\u003cli data-start=\"164\" data-end=\"303\"\u003e\n\u003cp data-start=\"166\" data-end=\"303\"\u003eThe APD-100 is a \u003cstrong data-start=\"183\" data-end=\"212\"\u003eSingle Window Annunciator\u003c\/strong\u003e from EAPL, designed for monitoring and signaling alarm conditions in industrial systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"304\" data-end=\"401\"\u003e\n\u003cp data-start=\"306\" data-end=\"401\"\u003eProvides \u003cstrong data-start=\"315\" data-end=\"366\"\u003evisual (LED) and audible (buzzer\/hooter) alarms\u003c\/strong\u003e for process or equipment faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"402\" data-end=\"482\"\u003e\n\u003cp data-start=\"404\" data-end=\"482\"\u003eCompact and DIN-rail mountable design with easy wiring and robust enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"483\" data-end=\"585\"\u003e\n\u003cp data-start=\"485\" data-end=\"585\"\u003eDesigned for reliable alarm annunciation in control panels, MCCs, DG sets, and process industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"587\" data-end=\"590\"\u003e\n\u003ch2 data-start=\"592\" data-end=\"617\"\u003e\u003cstrong data-start=\"595\" data-end=\"617\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"619\" data-end=\"1485\"\u003e\n\u003cli data-start=\"619\" data-end=\"683\"\u003e\n\u003cp data-start=\"621\" data-end=\"683\"\u003eFunction: Single-window annunciator with audio-visual alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"684\" data-end=\"740\"\u003e\n\u003cp data-start=\"686\" data-end=\"740\"\u003eSupply Voltage: Universal range 90 V to 270 V AC\/DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"741\" data-end=\"819\"\u003e\n\u003cp data-start=\"743\" data-end=\"819\"\u003eAlarm Indication: Bright LED visual indication with audible buzzer\/hooter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"820\" data-end=\"911\"\u003e\n\u003cp data-start=\"822\" data-end=\"838\"\u003eReset Options:\u003c\/p\u003e\n\u003cul data-start=\"841\" data-end=\"911\"\u003e\n\u003cli data-start=\"841\" data-end=\"872\"\u003e\n\u003cp data-start=\"843\" data-end=\"872\"\u003eManual reset (push button).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"911\"\u003e\n\u003cp data-start=\"877\" data-end=\"911\"\u003eRemote reset (external contact).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"912\" data-end=\"1012\"\u003e\n\u003cp data-start=\"914\" data-end=\"1012\"\u003eOutput Contact: 1 Change-over (C\/O) relay contact, rated 5 A at 250 VAC \/ 28 VDC resistive load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1013\" data-end=\"1042\"\u003e\n\u003cp data-start=\"1015\" data-end=\"1042\"\u003ePower Consumption: ≤3 VA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1043\" data-end=\"1111\"\u003e\n\u003cp data-start=\"1045\" data-end=\"1111\"\u003eEnclosure: Compact, modular design, DIN-rail or panel mountable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1112\" data-end=\"1174\"\u003e\n\u003cp data-start=\"1114\" data-end=\"1174\"\u003eTerminals: Screw-type with clear markings for easy wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1175\" data-end=\"1335\"\u003e\n\u003cp data-start=\"1177\" data-end=\"1201\"\u003eEnvironmental Ratings:\u003c\/p\u003e\n\u003cul data-start=\"1204\" data-end=\"1335\"\u003e\n\u003cli data-start=\"1204\" data-end=\"1248\"\u003e\n\u003cp data-start=\"1206\" data-end=\"1248\"\u003eOperating temperature: –10 °C to +55 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1251\" data-end=\"1293\"\u003e\n\u003cp data-start=\"1253\" data-end=\"1293\"\u003eStorage temperature: –25 °C to +80 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1296\" data-end=\"1335\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1335\"\u003eHumidity: Up to 85–95% RH at 40 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1336\" data-end=\"1424\"\u003e\n\u003cp data-start=\"1338\" data-end=\"1424\"\u003eService Life: Long electrical and mechanical durability under industrial conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1425\" data-end=\"1485\"\u003e\n\u003cp data-start=\"1427\" data-end=\"1485\"\u003eDimensions: Approx. 17.5 mm (W) × 90 mm (H) × 63 mm (D).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1487\" data-end=\"1490\"\u003e\n\u003ch2 data-start=\"1492\" data-end=\"1511\"\u003e\u003cstrong data-start=\"1495\" data-end=\"1511\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1513\" data-end=\"1935\"\u003e\n\u003cli data-start=\"1513\" data-end=\"1559\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1559\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1533\"\u003eControl Panels\u003c\/strong\u003e for fault annunciation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1625\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1625\"\u003e\u003cstrong data-start=\"1562\" data-end=\"1594\"\u003eMotor Control Centers (MCCs)\u003c\/strong\u003e for motor protection alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1626\" data-end=\"1700\"\u003e\n\u003cp data-start=\"1628\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1628\" data-end=\"1662\"\u003eDG sets and transformer panels\u003c\/strong\u003e for monitoring abnormal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1701\" data-end=\"1776\"\u003e\n\u003cp data-start=\"1703\" data-end=\"1776\"\u003e\u003cstrong data-start=\"1703\" data-end=\"1725\"\u003eProcess industries\u003c\/strong\u003e to indicate system trips, failures, or warnings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1860\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1860\"\u003e\u003cstrong data-start=\"1779\" data-end=\"1801\"\u003eAutomation systems\u003c\/strong\u003e for alerting operators to faults or abnormal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1861\" data-end=\"1935\"\u003e\n\u003cp data-start=\"1863\" data-end=\"1935\"\u003e\u003cstrong data-start=\"1863\" data-end=\"1906\"\u003eBuilding management and utility systems\u003c\/strong\u003e requiring alarm signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1937\" data-end=\"1940\"\u003e\n\u003ch2 data-start=\"1942\" data-end=\"1956\"\u003e\u003cstrong data-start=\"1945\" data-end=\"1956\"\u003eSummary\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1958\" data-end=\"2381\"\u003e\n\u003cli data-start=\"1958\" data-end=\"2057\"\u003e\n\u003cp data-start=\"1960\" data-end=\"2057\"\u003eThe \u003cstrong data-start=\"1964\" data-end=\"1975\"\u003eAPD-100\u003c\/strong\u003e is a compact, reliable single-window annunciator with universal supply voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2058\" data-end=\"2142\"\u003e\n\u003cp data-start=\"2060\" data-end=\"2142\"\u003eProvides \u003cstrong data-start=\"2069\" data-end=\"2098\"\u003evisual and audible alarms\u003c\/strong\u003e, with manual and remote reset capability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2143\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2145\" data-end=\"2217\"\u003eFeatures a change-over relay output for external signaling or control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2218\" data-end=\"2287\"\u003e\n\u003cp data-start=\"2220\" data-end=\"2287\"\u003eEasy to mount on DIN-rail and designed for robust industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2288\" data-end=\"2381\"\u003e\n\u003cp data-start=\"2290\" data-end=\"2381\"\u003eIdeal for MCCs, control panels, DG\/transformer panels, and process automation industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50648625119520,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/ChatGPTImageAug30_2025_05_04_41AM.png?v=1756515943"},{"product_id":"apd-300","title":"APD-300","description":"\u003ch2 data-start=\"126\" data-end=\"162\"\u003e\u003cstrong data-start=\"129\" data-end=\"162\"\u003eAPD-300 – Product Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"164\" data-end=\"583\"\u003e\n\u003cli data-start=\"164\" data-end=\"270\"\u003e\n\u003cp data-start=\"166\" data-end=\"270\"\u003eThe APD-300 is a \u003cstrong data-start=\"183\" data-end=\"211\"\u003eThree Window Annunciator\u003c\/strong\u003e from EAPL designed for \u003cstrong data-start=\"235\" data-end=\"267\"\u003emulti-point alarm monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"271\" data-end=\"394\"\u003e\n\u003cp data-start=\"273\" data-end=\"394\"\u003eProvides \u003cstrong data-start=\"282\" data-end=\"308\"\u003evisual LED indications\u003c\/strong\u003e and an \u003cstrong data-start=\"316\" data-end=\"333\"\u003eaudible alarm\u003c\/strong\u003e for up to three independent faults or abnormal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"395\" data-end=\"482\"\u003e\n\u003cp data-start=\"397\" data-end=\"482\"\u003eCompact, DIN-rail mountable design, ideal for use in control and protection panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"483\" data-end=\"583\"\u003e\n\u003cp data-start=\"485\" data-end=\"583\"\u003eAllows operators to quickly identify fault locations, improving response time and system safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"585\" data-end=\"588\"\u003e\n\u003ch2 data-start=\"590\" data-end=\"615\"\u003e\u003cstrong data-start=\"593\" data-end=\"615\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"617\" data-end=\"1521\"\u003e\n\u003cli data-start=\"617\" data-end=\"680\"\u003e\n\u003cp data-start=\"619\" data-end=\"680\"\u003eFunction: Three-window annunciator with audio-visual alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"681\" data-end=\"743\"\u003e\n\u003cp data-start=\"683\" data-end=\"743\"\u003eSupply Voltage: Universal input range 90 V to 270 V AC\/DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"744\" data-end=\"881\"\u003e\n\u003cp data-start=\"746\" data-end=\"766\"\u003eAlarm Indications:\u003c\/p\u003e\n\u003cul data-start=\"769\" data-end=\"881\"\u003e\n\u003cli data-start=\"769\" data-end=\"827\"\u003e\n\u003cp data-start=\"771\" data-end=\"827\"\u003eThree separate LED windows for three different faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"830\" data-end=\"881\"\u003e\n\u003cp data-start=\"832\" data-end=\"881\"\u003eAudible alarm (buzzer\/hooter) for active fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"979\"\u003e\n\u003cp data-start=\"884\" data-end=\"900\"\u003eReset Options:\u003c\/p\u003e\n\u003cul data-start=\"903\" data-end=\"979\"\u003e\n\u003cli data-start=\"903\" data-end=\"940\"\u003e\n\u003cp data-start=\"905\" data-end=\"940\"\u003eManual reset (front push button).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"943\" data-end=\"979\"\u003e\n\u003cp data-start=\"945\" data-end=\"979\"\u003eRemote reset (external contact).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"980\" data-end=\"1080\"\u003e\n\u003cp data-start=\"982\" data-end=\"1080\"\u003eOutput Contact: 1 Change-over (C\/O) relay contact, rated 5 A at 250 VAC \/ 28 VDC resistive load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1081\" data-end=\"1110\"\u003e\n\u003cp data-start=\"1083\" data-end=\"1110\"\u003ePower Consumption: ≤3 VA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1111\" data-end=\"1171\"\u003e\n\u003cp data-start=\"1113\" data-end=\"1171\"\u003eEnclosure: Modular, compact DIN-rail\/panel mount design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1172\" data-end=\"1227\"\u003e\n\u003cp data-start=\"1174\" data-end=\"1227\"\u003eTerminals: Screw-type with clear terminal markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1228\" data-end=\"1388\"\u003e\n\u003cp data-start=\"1230\" data-end=\"1254\"\u003eEnvironmental Ratings:\u003c\/p\u003e\n\u003cul data-start=\"1257\" data-end=\"1388\"\u003e\n\u003cli data-start=\"1257\" data-end=\"1301\"\u003e\n\u003cp data-start=\"1259\" data-end=\"1301\"\u003eOperating temperature: –10 °C to +55 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1304\" data-end=\"1346\"\u003e\n\u003cp data-start=\"1306\" data-end=\"1346\"\u003eStorage temperature: –25 °C to +80 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1349\" data-end=\"1388\"\u003e\n\u003cp data-start=\"1351\" data-end=\"1388\"\u003eHumidity: Up to 85–95% RH at 40 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1389\" data-end=\"1462\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1462\"\u003eService Life: Long mechanical and electrical life with rugged design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1463\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1465\" data-end=\"1521\"\u003eDimensions: Approx. 35 mm (W) × 90 mm (H) × 63 mm (D).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1523\" data-end=\"1526\"\u003e\n\u003ch2 data-start=\"1528\" data-end=\"1547\"\u003e\u003cstrong data-start=\"1531\" data-end=\"1547\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1549\" data-end=\"2004\"\u003e\n\u003cli data-start=\"1549\" data-end=\"1616\"\u003e\n\u003cp data-start=\"1551\" data-end=\"1616\"\u003e\u003cstrong data-start=\"1551\" data-end=\"1583\"\u003eControl \u0026amp; Relay panels (C\u0026amp;R)\u003c\/strong\u003e for system fault annunciation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1617\" data-end=\"1691\"\u003e\n\u003cp data-start=\"1619\" data-end=\"1691\"\u003e\u003cstrong data-start=\"1619\" data-end=\"1651\"\u003eMotor Control Centers (MCCs)\u003c\/strong\u003e for multiple motor protection alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1692\" data-end=\"1764\"\u003e\n\u003cp data-start=\"1694\" data-end=\"1764\"\u003e\u003cstrong data-start=\"1694\" data-end=\"1728\"\u003eDG sets and transformer panels\u003c\/strong\u003e to monitor multiple fault points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1765\" data-end=\"1847\"\u003e\n\u003cp data-start=\"1767\" data-end=\"1847\"\u003e\u003cstrong data-start=\"1767\" data-end=\"1796\"\u003eIndustrial process plants\u003c\/strong\u003e for equipment trip, failure, or warning signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1848\" data-end=\"1912\"\u003e\n\u003cp data-start=\"1850\" data-end=\"1912\"\u003e\u003cstrong data-start=\"1850\" data-end=\"1872\"\u003eAutomation systems\u003c\/strong\u003e needing multi-point alarm indication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1913\" data-end=\"2004\"\u003e\n\u003cp data-start=\"1915\" data-end=\"2004\"\u003e\u003cstrong data-start=\"1915\" data-end=\"1947\"\u003eBuilding and utility systems\u003c\/strong\u003e requiring three-point monitoring with alarm signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2006\" data-end=\"2009\"\u003e\n\u003ch2 data-start=\"2011\" data-end=\"2025\"\u003e\u003cstrong data-start=\"2014\" data-end=\"2025\"\u003eSummary\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2027\" data-end=\"2537\"\u003e\n\u003cli data-start=\"2027\" data-end=\"2124\"\u003e\n\u003cp data-start=\"2029\" data-end=\"2124\"\u003eThe \u003cstrong data-start=\"2033\" data-end=\"2044\"\u003eAPD-300\u003c\/strong\u003e is a robust \u003cstrong data-start=\"2057\" data-end=\"2085\"\u003ethree-window annunciator\u003c\/strong\u003e supporting three independent alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2125\" data-end=\"2224\"\u003e\n\u003cp data-start=\"2127\" data-end=\"2224\"\u003eProvides \u003cstrong data-start=\"2136\" data-end=\"2187\"\u003eclear LED fault indication and an audible alarm\u003c\/strong\u003e, ensuring quick fault recognition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2225\" data-end=\"2320\"\u003e\n\u003cp data-start=\"2227\" data-end=\"2320\"\u003eUniversal input supply and compact DIN-rail design make it versatile for panel integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2407\"\u003e\n\u003cp data-start=\"2323\" data-end=\"2407\"\u003eIncludes manual and remote reset with relay output for external signaling\/control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2408\" data-end=\"2537\"\u003e\n\u003cp data-start=\"2410\" data-end=\"2537\"\u003eIdeal for MCCs, C\u0026amp;R panels, DG\/transformer panels, and process automation where \u003cstrong data-start=\"2490\" data-end=\"2522\"\u003emulti-point fault monitoring\u003c\/strong\u003e is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50648630296864,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/ChatGPTImageAug30_2025_05_04_41AM.png?v=1756515943"},{"product_id":"apd-600","title":"APD - 600","description":"\u003cp data-start=\"173\" data-end=\"498\"\u003eThe APD-600 is a high-performance anti-pumping relay designed for medium and low-voltage switchgear and control panels. It prevents repeated or unintended re-closing of circuit breakers or contactors when the closing circuit remains engaged, thereby protecting your equipment and enhancing system reliability.\u003c\/p\u003e\n\u003cp data-start=\"500\" data-end=\"519\"\u003e\u003cstrong data-start=\"500\" data-end=\"517\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"520\" data-end=\"1282\"\u003e\n\u003cli data-start=\"520\" data-end=\"667\"\u003e\n\u003cp data-start=\"522\" data-end=\"667\"\u003ePrevents “pumping” — that is, a close command being held while a fault or trip condition still exists, resulting in repeated close-open cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"668\" data-end=\"874\"\u003e\n\u003cp data-start=\"670\" data-end=\"874\"\u003eRapid response: The product listing indicates a response time of approximately 20 ms for the APD-600 (“Rly 4C\/O. ‘X’ Vtg. 20 mS”) which implies very fast operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"994\"\u003e\n\u003cp data-start=\"877\" data-end=\"994\"\u003eFour change-over (C\/O) relay contacts for flexible wiring or interlock logic. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"995\" data-end=\"1130\"\u003e\n\u003cp data-start=\"997\" data-end=\"1130\"\u003e“X-Vtg” (wide-voltage) variant offering flexibility across control-voltages and applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.switchgearandautomation.com\/eapl-pricelist\/EAPL_%20PRICE%20LIST_01.04.25.pdf?utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.switchgearandautomation.com\/eapl-pricelist\/EAPL_%20PRICE%20LIST_01.04.25.pdf?utm_source=chatgpt.com\" class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]!\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between\"\u003e\u003cspan class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1131\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1133\" data-end=\"1282\"\u003eCompact, panel-friendly format, facilitating installation in MCCs, automation panels and distribution boards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1284\" data-end=\"1303\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1301\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1304\" data-end=\"1758\"\u003e\n\u003cli data-start=\"1304\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1306\" data-end=\"1495\"\u003eUse in motor control centres (MCCs) and control panels where circuit-breaker\/contactor closing coils are used and there’s a risk of holding the close push-button beyond the safe interval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1649\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1649\"\u003eIdeal for switchgear assemblies in industrial plants, utilities, commercial buildings and any system requiring protected, reliable breaker operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1650\" data-end=\"1758\"\u003e\n\u003cp data-start=\"1652\" data-end=\"1758\"\u003eSuitable for systems requiring both safety interlocking and indication logic due to its multiple contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":50749809983776,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/files\/ChatGPTImageSep30_2025_04_11_23PM.png?v=1759260016"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8512\/5152\/collections\/ChatGPT_Image_Aug_30_2025_05_30_00_AM.png?v=1759777525","url":"https:\/\/starpowerelectrical.com\/collections\/anti-pumping-relays.oembed","provider":"My Store","version":"1.0","type":"link"}